Bytes 04 through 07 - First Block Location
The First Block Location field indicates the block address associated
with the current logical block position (that is, the block address of
the next data block to be transferred between the initiator and the CTS
if a READ or WRITE command is issued). When using a LOCATE
command to search for this position, specify the value returned for
this field as the Block Address in bytes 03 through 06 of the LOCATE
CDB.
Note: If you issue a READ POSITION command immediately after
issuing a REWIND immediate command (Immed bit set to 1)
and you were writing data, the position returned by the CTS
may still reflect where the next write operation would have
occurred (not yet reset to 00 00 00 00).
Bytes 08 through 11 - Last Block Location
The Last Block Location field is not valid for the CTS. The value
returned for this field is 0.
Bytes 13 through 15 - Number of Blocks in Buffer
The Number of Blocks in Buffer field is not valid for the CTS. The
value returned for this field is 0.
Bytes 16 through 19 - Number of Bytes in Buffer
The Number of Bytes in Buffer field is not valid for the CTS. The
value returned for this field is 0.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
15-5
15 READ POSITION (34h)