10.14 Vendor Unique Parameters Page 1
(Page Code=20h)
Bit
Byte
76543210
00 Reserved Page Code
01 Page Length
02 CT RSVD ND RSVD NBE EBD PE NAL
03 RTF WTF RSVD 112m
04 Motion Threshold
05 Gap Threshold
Byte 00, Bits 5 through 0 - Page Code
The Page Code identifies the page being transferred. The valid value
is 20h (Vendor Unique Parameters Page 1).
Byte 01 - Page Length
The Page Length indicates the number of bytes in the Vendor Unique
Parameters Page 1 that follow this byte. The valid value is 04h.
Byte 02, Bit 7 - CT (Cartridge Type)
The CT bit works in conjunction with the 112m bit (byte 03, bit 0) to
indicate the size of the data cartridge that is expected to be loaded in
the CTS. Refer to Table 10-10 on page 10-21 for the combinations of
settings for the CT and 112m bits.
Notes:
If you are using 160m XL data cartridges with an EXB-8505XL or
EXB-8205XL, the CTS ignores the settings of the CT and 112m bits.
You can set the CT bit only when the tape is positioned at LBOT.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
10-51