10.11 Data Compression Page
(Page Code=0Fh)
The Data Compression Page specifies parameters for the control of
data compression.
EXB-8505 For the EXB-8505, this page allows you to turn data compression on
or off in 8500c format independently of the tape’s position. When the
EXB-8505 writes data in 8200c format, the data is always compressed.
Compression cannot be controlled by the user.
EXB-8205 When the EXB-8205 writes data in 8200c format, the data is always
compressed. Compression cannot be controlled by the user. For the
EXB-8205, this page provides driver compatibility with products that
support the control of data compression.
Bit
Byte
76543210
00 RSVD Page Code
01 Page Length
02 DCE DCC Reserved
03 DDE RED Reserved
04 (MSB)
Compression Algorithm
07 (LSB)
08 (MSB)
Decompression Algorithm
11 (LSB)
12
Reserved
15