Exabyte EXB-8205 Instrucciones de operaciones Pagina 239

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 446
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 238
Compression Errors
The CTS can report two types of compression errors during a read
operation:
If the compression circuit is unable to decompress previously
compressed data during a read operation, the CTS returns Check
Condition status. The REQUEST SENSE data is set as follows:
Sense Key Hardware Error (4h)
ASC 11h
ASCQ 00h
FSC 18h
If the read decompression CRC fails during a read operation, the
CTS returns Check Condition status. The REQUEST SENSE data
is set as follows:
Sense Key Hardware Error (4h)
ASC 11h
ASCQ 02h
FSC 19h
To recover from either of these errors, follow these steps:
1. Reissue the failed command or command sequence.
2. Power the CTS off and back on again.
or
Send a SCSI bus reset (“hard” reset).
If the error persists, the CTS requires service.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
12-11
12 READ (08h)