Byte 02, Bit 7 – Disable Update (DU)
The DU bit indicates whether updates to the current cumulative value
are enabled or disabled, as follows:
0 – The CTS can update the current cumulative value, so comparisons
of the current cumulative value and the threshold value can occur
normally.
1 – The CTS will not update the current cumulative value, so
threshold conditions will not be met for this counter.
Important
If you want the CTS to compare the current cumulative value
to the threshold value for the counter and to return Unit
Attention when the threshold criteria are met, first issue a
MODE SELECT (15h) command and send the Control Mode
page(PageCode=0Ah)withtheRLECbitsetto1.
Then, set the DU bit to 0 and the ETC bit to 1.
Byte 02, Bit 6 – Disable Save (DS)
This field is ignored by the CTS.
Byte 02, Bit 5 – Target Save Disable (TSD)
This field is ignored by the CTS.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
8-9
8 LOG SELECT (4Ch)