8.4 Log Parameters
Zero or more log parameters follow the Parameter List Header. Each
log parameter includes four bytes of descriptive information followed
by a variable-length parameter value. There is no required order for
the log parameters.
The format of a log parameter is as follows:
Bit
Byte
76543210
00 (MSB)
Parameter Code
01 (LSB)
02 DU DS TSD ETC TMC RSVD LP
03 Parameter Length
04 (MSB)
Parameter Value
nn
(LSB)
Bytes 00 and 01 – Parameter Code
As shown in Table 8-2, the Parameter Code field specifies the code of
the counter for which you want to set the threshold or cumulative
value.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
8-7
8 LOG SELECT (4Ch)