12.3 Exceptions and Error Conditions
The following exceptions and error conditions can occur with the
READ command.
Filemark Detected
If the CTS detects a filemark before completing the read operation, it
returns Check Condition status. The REQUEST SENSE data is set as
follows:
Valid 1
Filemark 1
Sense Key No Sense (0h)
Information
bytes
Depend on the setting of the Fixed bit, as follows:
■ If the Fixed bit is 0, equal the requested transfer length
■ If the Fixed bit is 1, equal the difference between the
requested transfer length and the actual number of
logical blocks read.
ASC 00h
ASCQ 01h
FSC 0Dh
When the READ command terminates, the logical position is at the
EOT side of the filemark encountered.
12-4
EXB-8205 and EXB-8505
(Standard and XL)
510503
12 READ (08h)