10.18 Tape Format Examples
ThissectionprovidesexamplesforusingtheCTStowrite,appendto,
and read tapes in the following formats:
8500c format (EXB-8505)
8500 format (EXB-8505)
8200c format
8200 format
As you review and use the examples in this section, keep the
following rules in mind:
The CTS allows only one format on any one tape.
If you are writing data, you must decide on the tape’s format at
LBOT. This is because the LBOT blocks define the format for the
tape. If you do not select a format, the CTS writes in the
power-on default format.
Note: To rewrite the tape in a different format, you must
overwrite the previously written LBOT pattern by issuing
a WRITE (0Ah) or WRITE FILEMARKS (10h) command at
LBOT.
If you are appending to a previously written tape at a location
other than LBOT, the CTS automatically writes in the format of
the data already on the tape.
If you are reading a previously written tape, the CTS
automatically determines the tape’s format for you. However, you
can determine the format for yourself by following these steps:
1. Load the data cartridge in the CTS.
2. Issue a MODE SENSE (1Ah) command.
3. Look at the Density Code in the Block Descriptor or the RTF
field in the Vendor Unique Parameters Page 1 (Page
Code=20h).
If you are using the EXB-8505 with a tape that has been formatted
with two partitions, you must read and write data in 8500c
format. If you attempt to change the format of the tape, you will
destroy the partition information.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
10-61
10 MODE SELECT (15h) andMODE SENSE (1Ah)