SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
15-1
15
READ ELEMENT STATUS
(B8h)
15.1 ABOUT THIS COMMAND
The READ ELEMENT STATUS command requests that the autoloader return
the status of its elements. This command returns the data created as a result of
the INITIALIZE ELEMENT STATUS (07h) or INITIALIZE ELEMENT STATUS
WITH RANGE (E7h) command. For more information about these commands,
see Chapter 4 and Chapter 5.
Bit
Byte
7 6 5 4 3 2 1 0
00 10111000
01 Reserved VolTag Element Type Code
02 (MSB)
Starting Element Address
(LSB)
03
04 (MSB)
Number of Elements
(LSB)
05
06 Reserved CurData DVCID
07 (MSB)
Allocation Length
(LSB)
08
09
10 Reserved
11 S/N Req Reserved 0 0